Difference between revisions of "Tools/Manuals/TS88"
< Tools
Jump to navigation
Jump to search
(Created page with '{{TOC_right}} Category:FAQ ------ Back to Troubleshooting Guide ------ = WMS does not consider close SE = == Full message == The BDI…') |
|||
Line 1: | Line 1: | ||
{{Template:Op menubar}} | |||
{{Template:Doc_menubar}} | |||
[[Category:Operations Manuals]] | |||
{{TOC_right}} | {{TOC_right}} | ||
------ | ------ | ||
Back to [[Tools/Manuals/SiteProblemsFollowUp|Troubleshooting Guide]] | Back to [[Tools/Manuals/SiteProblemsFollowUp|Troubleshooting Guide]] |
Latest revision as of 13:49, 23 November 2012
Main | EGI.eu operations services | Support | Documentation | Tools | Activities | Performance | Technology | Catch-all Services | Resource Allocation | Security |
Documentation menu: | Home • | Manuals • | Procedures • | Training • | Other • | Contact ► | For: | VO managers • | Administrators |
Back to Troubleshooting Guide
WMS does not consider close SE
Full message
The BDII shows a particular SE to be close to a particular CE:
$ ldapsearch -x -h lcg-bdii.cern.ch:2170 -b o=grid \ GlueCESEBindGroupSEUniqueID=some-SE.site.domain [...] GlueCESEBindGroupCEUniqueID: some-CE.site.domain:8443/cream-pbs-queue [...] GlueCESEBindGroupSEUniqueID: some-SE.site.domain
But a WMS job description requiring that close SE does not match the given CE:
Requirements = Member("some-SE.site.domain", other.GlueCESEBindGroupSEUniqueID);
While the intended CE itself is matched fine:
Requirements = (other.GlueCEUniqueId == "some-CE.site.domain:8443/cream-pbs-queue");
Diagnosis
The CE host probably does not publish the GlueCESEBind record for that close SE. Example:
$ ldapsearch -x -h site-bdii.site.domain:2170 -b o=grid objectClass=GlueCESEBind [...] GlueCESEBindCEUniqueID: some-CE.site.domain:8443/cream-pbs-queue GlueCESEBindSEUniqueID: some-SE.site.domain [...]