Tools/Manuals/TS77
< Tools
Jump to navigation
Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Main | EGI.eu operations services | Support | Documentation | Tools | Activities | Performance | Technology | Catch-all Services | Resource Allocation | Security |
Documentation menu: | Home • | Manuals • | Procedures • | Training • | Other • | Contact ► | For: | VO managers • | Administrators |
Back to Troubleshooting Guide
GRAM Job submission failed because the job manager failed to open stderr (error code 74)
Full message
$ globus-job-run some-CE.domain /bin/hostname GRAM Job submission failed because the job manager failed to open stderr (error code 74)
Diagnosis
The UI does not have inbound connectivity for the GLOBUS_TCP_PORT_RANGE as defined on the UI.
Note: globus-job-run should only be used for tests, because for each job it causes a process to run on the CE until the job has exited.
Solution
- Set GLOBUS_TCP_PORT_RANGE appropriately.
- Fix firewall(s).
- Define GLOBUS_HOSTNAME as the fully qualified external hostname in case the hostname command returns a short or local name for the host.